Configure Automatic Scrap Data Collection

Learn how to configure machine signals in GS Desktop to automatically register scrap quantities and associate them with the correct Measure Point and Scrap Reason.

Overview

Good Solutions can automatically collect scrap information directly from production equipment.

A Scrap Signal registers a pulse when scrap is detected by a machine or external sensor. This allows Good Solutions to record scrap without requiring an operator to enter every occurrence manually.

Automatic scrap collection helps production teams:

  • Monitor quality losses more consistently.
  • Reduce manual registration.
  • Identify when and where scrap occurs.
  • Analyze scrap quantities and reasons.
  • Improve the accuracy of production quality reporting.

How Does a Scrap Signal Work?

A Scrap Signal typically comes from a machine sensor, PLC, or another connected device.

For example, a packaging machine might generate a pulse every time a defective package is rejected.

Good Solutions receives the signal and registers the corresponding scrap quantity.

A Scrap Factor determines how many scrapped units each signal represents.

Scrap pulses Scrap Factor Registered scrap
10 1 10 units
10 2 20 units
10 5 50 units

The factor is useful when a single machine signal represents multiple scrapped products.

Before You Begin

Make sure that:

  • The machine has a suitable scrap signal.
  • The signal is available through a configured I/O interface.
  • The correct Measure Point exists in GS Desktop.
  • The relevant Scrap Reason has been configured.
  • You know how many scrapped units each pulse represents.

Step 1: Create a Scrap Signal Connection

  1. Open GS Desktop.
  2. Navigate to Settings → Machine Data.
  3. Select Scrap Signal Connections.
  4. Click Create.

A new Scrap Signal connection is created.

Step 2: Select the Machine Input

  1. Locate I/O-Interface Input.
  2. Click the connection icon.
  3. Select the correct I/O interface and input.
  4. Click Save and Close.

Make sure the selected input corresponds to the machine's scrap signal.

Step 3: Connect the Signal to a Measure Point

  1. Click the Measure Point connection icon.
  2. Select the Measure Point that should receive the scrap registrations.
  3. Save the selection.

The signal is now associated with the correct production equipment.

Step 4: Assign a Scrap Reason

You can associate a Scrap Reason with the signal so that registered scrap is automatically categorized.

  1. Click the Scrap Reason connection icon.
  2. Select the Scrap Reason you want to use.
  3. Click Save and Close.

For example, a signal from an automatic rejection system might be associated with a reason such as Defective Packaging.

Tip: Use a Scrap Reason that accurately describes what the signal detects. A general rejection signal may not provide enough information to distinguish between different defect types.

Step 5: Configure the Scrap Factor

Set the Scrap Factor to represent the number of scrapped units registered per pulse.

For example:

  • Factor 1: Each pulse represents one scrapped product.
  • Factor 2: Each pulse represents two scrapped products.
  • Factor 4: Each pulse represents four scrapped products.

Choose the factor according to the machine's actual signal behavior.

Step 6: Save the Configuration

  1. Review the I/O input.
  2. Confirm the Measure Point.
  3. Confirm the Scrap Reason.
  4. Verify the Scrap Factor.
  5. Click Save and Close.

The Scrap Signal connection is now configured.

Verify Your Configuration

After saving, test the configuration using a known number of scrap events.

Example:

A machine rejects five defective products and generates one pulse for each rejection.

With a Scrap Factor of 1, Good Solutions should register five scrapped units.

Check that:

  • The correct quantity is registered.
  • Scrap is associated with the intended Measure Point.
  • The selected Scrap Reason is used.
  • The information appears correctly in the relevant production and quality views.

Common Problems

Scrap is not registered

Check the physical input, I/O connection, and Measure Point association.

Scrap quantities are incorrect

Verify the Scrap Factor and the number of pulses generated by the machine.

Scrap appears under the wrong reason

Review the Scrap Reason associated with the signal.

Scrap appears under the wrong machine

Check the Measure Point connection.

Key Takeaways

  • Scrap Signals allow automatic registration of defective production.
  • Each signal must be connected to an I/O input and Measure Point.
  • Scrap Reasons can be assigned automatically.
  • The Scrap Factor determines how many units each pulse represents.
  • Always validate the configuration against actual machine events.